Bore & Stroke (mm) 105 x 130
Displacement (L) 6.75
N° of Cylinders 6
Cylinders Arrangement In line
Fuel System Mechanical
Governor (Gov.) Electronic
Aspiration (Asp.) Turbocharged & air-to-air cooled
Standard Equipment
Engine and block
Cast iron gantry type structure block
One-piece forged crankshaft
Separate cast iron cylinder heads and wet liners
Aluminum alloy pistons with oil cooling gallery
Cooling System
Radiator and hoses supplied directly mounted on the engine
Thermostatically-controlled system with belt drivencoolant pump and pusher fan
Lubrication system
Flat bottom large capacity oil pan
Spin-on full-flow lube oil filter
Fuel system
P type fuel injection pump and injector for higher inject pressure
Duplex fine filter for better efficiency
Air intake and exhaust system
Mid-position and below inlet turbocharger optimized for genset application
Special rear mounted air filter with restriction indicator
Exhaust manifold shield for heat isolating
Electrical System
12 Vdc electric starter motor and battery charging alternator for 1500 Rpm engines
24 Vdc electric starter motor and battery charging alternator for 1800 Rpm engines
LOP + HWT sensors
Flywheel and housing
SAE 3 flywheel housing and 11.5” flywheel for 1500 Rpm
SAE 1 flywheel housing and 14” flywheel for 1800 Rpm
Ratings definitions
Emergency Standby Power (ESP)
Emergency Standby Power is the maximum power available for a varying load for the duration of a main power network
failure. The average load factor over 24 hours of operation should not exceed 70% of the engine’s ESP power rating.
Typical operational hours of the engine is 200 hours per year, with a maximum usage of 500 hours per year. This includes
an annual maximum of 25 hours per year at the ESP power rating. No overload capability is allowed. The engine is not to
be used for sustained utility paralleling applications.
Continuous Power (COP)
Continuous Power is the maximum power available for an unlimited period of use at a constant load factor. No overload
capability is allowed.
Prime Rated Power (PRP)
Prime Power is the maximum power available for unlimited hours of usage in a variable load application. The average load
factor should not exceed 70% of the engine’s PRP power rating during any 24 hour period. An overload capability of 10%
is available, however, this is limited to 1 hour within every 12 hour period.